The x-ray source consists of the x-ray tube, high voltage power supply and the control all integrated into one complete unit. X-ray sources can be used for a vast variety of applications and purposes. It is especially helpful, when a small footprint, easy integration and cost efficiency is required in one single solution.

Our integrated x-ray sources are very versatile and can be adapted into every solution. One of the most important parameters in the integrated x-ray source is the x-ray tube. In a well-designed x-ray source, there needs to be a balance between focal spot, power, cost and tube stability in order to create the best possible result.

We supply VJ, Spellman and Thermo Fisher’s integrated x-ray sources, please contact us for more detail products information.

VJ X-ray Generator

Model

KV

mA

Spot Size(mm)

Max Rating

Target Angle(°)

Data Sheet

IXS041K

40

25

1.3 mm as per EN12543 ( 0.5 Nominal IEC60336

1KW

60 (Fan beam)

(Cone Beam available upon request)


IXS0520

50

4

0.4-0.8 nominal as per IEC60336

80W continuous/ 200W peak

80 X 10, 74 X 12 (Fan beam)

25 (Cone beam)

IXS0803

80

1

0.8 nominal as per IEC60336

30W

20 (Cone beam)

IXS0808

80

1

0.8 nominal as per IEC60336

80W

80 X 10 (Fan beam)

30 (Cone beam)

IXS0808 Mini-Focus

80

0.7

0.03-0.05

56W

80 X 10 (Fan beam)

30 (Cone beam)


IXS0835

80

8

0.5 nominal as per IEC60336

350W

45 (Fan beam)

IXS0850

80

12.5

1.2 mm as per EN12543
( <0.5 nominal IEC60336)

500W

90 (Fan beam)

IXS1010

100

2

0.8 nominal as per IEC60336

100W

80 X 10 (Fan beam)

30 (Cone beam)


IXS1015

100

6

0.8 nominal as per IEC60336

150W

80 X 10 (Fan beam)

30 (Cone beam)


IXS1020

100

8

0.8 nominal as per IEC60336

200W

80 X 10 (Fan beam)

30 (Cone beam)


IXS1050

100

10

0.4 nominal as per IEC60336

1KW

30 (Cone beam)

IXS1203

120

0.3

0.05

36W

80 X 10 (Fan beam)

30 (Cone beam)

IXS1212 Portable

120

1

0.5 nominal as per IEC60336

120W

60 (Fan beam)

35 (Cone beam)

IXS1620

160

8

0.8 nominal as per IEC60336

200W

80 X 10 (Fan beam)

30 (Cone beam)

IXS1650

160

8

0.8 nominal as per IEC60336

500W

80 X 10 (Fan beam)

30 (Cone beam)

IXS1680

160

10

1.2 nominal as per IEC60336

800W

80 X 10 (Fan beam)

30 (Cone beam)

IXS161K

160

8

1.5mmx1.6mm (For Ref. only) EN12543

1KW

90 X 15 (Fan beam)

IXS182K

180

13.3

2.4mm as per EN12543

2.394KW

120 X 10(Fan beam)

Spellman X-ray Generator

Model

KV

mA

Spot Size(mm)

Max Rating

Target Angle(°)

Data Sheet

XRB011

80

0.25 / 0.7

0.033-0.05

50W / 70W

40 (Cone beam)

XRB100N100

100

1

0.5


100W

74 X 10 (Fan beam)

XRB80N100

80


1.25

0.5

100W

25 (Cone beam)

XRB80PN100HR


80

2

0.8

100W

80 (Fan beam)

XRBD

160

1 / 2.1 /3.45/ 4

0.8

100W / 210W /350W / 500W

90 (Fan beam)

XRB160PN192

160

1.2

0.8 X 0.8

200W

80 X 10 (Fan beam)

Thermo Fisher X-ray Generator

Model

KV

mA

Spot Size(mm)

Max Rating

Target Angle(°)

Data Sheet

DXS11-5025

50

0.5

0.065

25W

34 X 49 (Fan beam)

DXS11-7020

70

0.2

0.03

14W

DXS11-8015

80

0.1

0.03

12W