Industrial X-ray Tubes

Industrial X-ray tubes are marked “I” and a variety of tubes are manufactured for each of the applicable fields (nondestructive testing, coating thickness gauging, etc.) Vacuum envelopes for industrial X-ray tubes are made of glass or ceramic. Ceramic envelopes are particularly strong mechanically, and this enables Canon Electron Tubes & Devices to offer X-ray generators with outstanding portability and operability.

Model

KV

mA

Spot Size(mm)

Max Rating (W)

Target Angle(°)

Target Material

Data Sheet

I-221

50

5

1

150

20

W

I-2118B

55

1

1x0.7

55

20

W

E7690

75

8

1x1

350

20

W

I-2112B

50

1

0.8

50

33

Rh

I-2113A

50

1.5

0.15

75

10

Mo

I-2115B

50

1.5

0.15

75

10

W, Mo

I-2122

50

1

0.15x0.1

50

16

W

I-2123

60

1.2

0.1

50

10

W

I-317

100

0.83

0.1

50

10

W

I-318

100

5

0.8

300

25

W